Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.712
Filtrar
1.
J Acoust Soc Am ; 155(3): 1813-1824, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38445988

RESUMO

This study assessed whether the effects of contralateral acoustic stimulation (CAS) are consistent with eliciting the medial olivocochlear (MOC) reflex for measurements sensitive to outer hair cell (otoacoustic emissions, OAEs), auditory-nerve (AN; compound action potential, CAP), and brainstem/cortical (envelope-following response, EFR) function. The effects of CAS were evaluated for simultaneous measurement of OAEs, CAPs, and EFRs in participants with normal hearing. Clicks were presented at 40 or 98 Hz in three ipsilateral noise conditions (no noise, 45 dB SPL, and 55 dB SPL). For the no noise condition, CAS suppressed or enhanced EFR amplitudes for 40- and 98-Hz clicks, respectively, while CAS had no significant effect on CAP amplitudes. A follow-up experiment using slower rates (4.4-22.2 Hz) assessed whether this insignificant CAS effect on CAPs was from ipsilateral MOC stimulation or AN adaptation; however, CAS effects remained insignificant despite favorable signal-to-noise ratios. CAS-related enhancements of EFR and CAP amplitudes in ipsilateral noise were not observed, contrary to the anti-masking effect of the MOC reflex. EFR and OAE suppression from CAS were not significantly correlated. Thus, the effects of CAS on EFRs may not be solely mediated by the MOC reflex and may be partially mediated by higher auditory centers.


Assuntos
Potenciais Evocados , Emissões Otoacústicas Espontâneas , Humanos , Potenciais de Ação , Estimulação Acústica , Reflexo
2.
Hear Res ; 445: 108995, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38518393

RESUMO

OBJECTIVE: The genotype-phenotype relationship in cisplatin-induced ototoxicity remains unclear. By assessing early shifts in distortion product otoacoustic emission (DPOAE) levels after initial cisplatin administration, we aimed to discriminate patients' susceptibility to cisplatin-induced ototoxicity and elucidate their genetic background. STUDY DESIGN: A prospective cross-sectional study. SETTING: Tertiary referral hospital in Japan. PATIENTS: Twenty-six patients with head and neck cancer were undergoing chemoradiotherapy with three cycles of 100 mg/m2 cisplatin. INTERVENTIONS: Repetitive pure-tone audiometry and DPOAE measurements, and blood sampling for DNA extraction were performed. Patients were grouped into early ototoxicity presence or absence based on whether DPOAE level shifts exceeded the corresponding reference limits of the 21-day test interval. MAIN OUTCOME MEASURES: Hearing thresholds after each cisplatin cycle, severity of other adverse events, and polymorphisms in cisplatin-induced ototoxicity-associated genes were compared. RESULTS: Early ototoxicity was present in 14 and absent in 12 patients. Ototoxicity presence on DPOAEs was associated with greater progression of hearing loss in frequencies ≥2 kHz throughout therapy and with higher ototoxicity grades compared with ototoxicity absence. Ototoxicity was further associated with grade ≥2 nausea. Ototoxicity presence was genetically associated with the GSTT1 null genotype and G-allele of NFE2L2 rs6721961, whereas ototoxicity absence was associated with the GSTM1 null genotype. Dose-dependent progression of hearing loss was the greatest in the combined genotype pattern of GSTT1 null and the T/G or G/G variants of rs6721961. CONCLUSION: Early DPOAE changes reflected genetic vulnerability to cisplatin-induced ototoxicity. Hereditary insufficiency of the antioxidant defense system causes severe cisplatin-induced hearing loss and nausea.


Assuntos
Cisplatino , Perda Auditiva , Fator 2 Relacionado a NF-E2 , Ototoxicidade , Humanos , Antineoplásicos/toxicidade , Cisplatino/toxicidade , Estudos Transversais , Surdez/induzido quimicamente , Perda Auditiva/induzido quimicamente , Perda Auditiva/diagnóstico , Perda Auditiva/genética , Náusea/induzido quimicamente , Fator 2 Relacionado a NF-E2/genética , Fator 2 Relacionado a NF-E2/farmacologia , Emissões Otoacústicas Espontâneas , Ototoxicidade/etiologia , Ototoxicidade/genética , Polimorfismo Genético , Estudos Prospectivos
3.
Hear Res ; 445: 108994, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38520899

RESUMO

African mole-rats display highly derived hearing that is characterized by low sensitivity and a narrow auditory range restricted to low frequencies < 10 kHz. Recently, it has been suggested that two species of these rodents do not exhibit distortion product otoacoustic emissions (DPOAE), which was interpreted as evidence for a lack of cochlear amplification. If true, this would make them unique among mammals. However, both theoretical considerations on the generation of DPOAE as well as previously published experimental evidence challenge this assumption. We measured DPOAE and stimulus-frequency otoacoustic emissions (SFOAE) in three species of African mole-rats (Ansell's mole-rat - Fukomys anselli; Mashona mole-rat - Fukomys darlingi; naked mole-rat - Heterocephalus glaber) and found unexceptional otoacoustic emission values. Measurements were complicated by the remarkably long, narrow and curved external ear canals of these animals, for which we provide a morphological description. Both DPOAE and SFOAE displayed the highest amplitudes near 1 kHz, which corresponds to the region of best hearing in all tested species, as well as to the frequency region of the low-frequency acoustic fovea previously described in Ansell's mole-rat. Thus, the cochlea in African mole-rats shares the ability to generate evoked otoacoustic emission with other mammals.


Assuntos
Cóclea , Emissões Otoacústicas Espontâneas , Animais , Emissões Otoacústicas Espontâneas/fisiologia , Cóclea/fisiologia , Audição , Testes Auditivos , Ratos-Toupeira
4.
Nat Commun ; 15(1): 1896, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429256

RESUMO

Inhibition of Notch signalling with a gamma-secretase inhibitor (GSI) induces mammalian hair cell regeneration and partial hearing restoration. In this proof-of-concept Phase I/IIa multiple-ascending dose open-label trial (ISRCTN59733689), adults with mild-moderate sensorineural hearing loss received 3 intratympanic injections of GSI LY3056480, in 1 ear over 2 weeks. Phase I primary outcome was safety and tolerability. Phase lla primary outcome was change from baseline to 12 weeks in average pure-tone air conduction threshold across 2,4,8 kHz. Secondary outcomes included this outcome at 6 weeks and change from baseline to 6 and 12 weeks in pure-tone thresholds at individual frequencies, speech reception thresholds (SRTs), Distortion Product Otoacoustic Emissions (DPOAE) amplitudes, Signal to Noise Ratios (SNRs) and distribution of categories normal, present-abnormal, absent and Hearing Handicap Inventory for Adults/Elderly (HHIA/E). In Phase I (N = 15, 1 site) there were no severe nor serious adverse events. In Phase IIa (N = 44, 3 sites) the average pure-tone threshold across 2,4,8 kHz did not change from baseline to 6 and 12 weeks (estimated change -0.87 dB; 95% CI -2.37 to 0.63; P = 0.252 and -0.46 dB; 95% CI -1.94 to 1.03; P = 0.545, respectively), nor did the means of secondary measures. DPOAE amplitudes, SNRs and distribution of categories did not change from baseline to 6 and 12 weeks, nor did SRTs and HHIA/E scores. Intratympanic delivery of LY3056480 is safe and well-tolerated; the trial's primary endpoint was not met.


Assuntos
Secretases da Proteína Precursora do Amiloide , Perda Auditiva Neurossensorial , Adulto , Idoso , Humanos , Audiometria de Tons Puros , Limiar Auditivo/fisiologia , Perda Auditiva Neurossensorial/tratamento farmacológico , Emissões Otoacústicas Espontâneas/fisiologia
5.
J Speech Lang Hear Res ; 67(2): 688-710, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38324255

RESUMO

PURPOSE: There is an increasing concern regarding hazardous recreational noise exposure among adolescents and young adults. Daily exposure to loud sound levels over a long period of time can increase the risk of noise-induced hearing loss. The full extent of the impact of recreational noise on hearing is not yet fully understood. The purpose of this review was to synthesize research that investigated hearing function in relation to recreational noise exposure in adolescents and young adults. METHOD: A systematic literature search of five databases covering the years 2000-2023 was performed. The articles included investigated audiological measurements of hearing function in relation to recreational noise exposure. RESULTS: Four hundred sixty records were identified, of which 20 met the inclusion criteria and were included in the results. This review showed that although some recreational noise activities can be potentially harmful, there is an unclear relationship between exposure and outcome. Some findings indicated hearing threshold shifts or reduced otoacoustic emission amplitudes after recreational noise exposure, but most changes were short term and in the extended high-frequency range. CONCLUSIONS: There seemed to be inconsistencies regarding the utilization of methods of measuring exposure and outcome between studies. This might be one reason for the differing results in studies on the reported impact on hearing function from recreational noise exposure. To draw more certain conclusions about long-term effects, there is a need for longitudinal research that utilizes sound level measurements to assess low and high degrees of recreational noise exposure in relation to hearing function. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.25114193.


Assuntos
Perda Auditiva Provocada por Ruído , Audição , Humanos , Adolescente , Adulto Jovem , Ruído/efeitos adversos , Perda Auditiva Provocada por Ruído/epidemiologia , Perda Auditiva Provocada por Ruído/etiologia , Emissões Otoacústicas Espontâneas , Testes Auditivos
6.
J Assoc Res Otolaryngol ; 25(2): 91-102, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409555

RESUMO

At the 2004 Midwinter Meeting of the Association for Research in Otolaryngology, Glenis Long and her colleagues introduced a method for measuring distortion-product otoacoustic emissions (DPOAEs) using primary-tone stimuli whose instantaneous frequencies vary continuously with time. In contrast to standard OAE measurement methods, in which emissions are measured in the sinusoidal steady state using discrete tones of well-defined frequency, the swept-tone method sweeps across frequency, often at rates exceeding 1 oct/s. The resulting response waveforms are then analyzed using an appropriate filter (e.g., by least-squares fitting). Although introduced as a convenient way of studying DPOAE fine structure by separating the total OAE into distortion and reflection components, the swept-tone method has since been extended to stimulus-frequency emissions and has proved an efficient and valuable tool for probing cochlear mechanics. One day-a long time coming-swept tones may even find their way into the audiology clinic.


Assuntos
Cóclea , Emissões Otoacústicas Espontâneas , Feminino , Humanos , Estimulação Acústica/métodos , Emissões Otoacústicas Espontâneas/fisiologia , Cóclea/fisiologia
7.
Acta otorrinolaringol. esp ; 75(1): 1-7, ene.-feb. 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-229265

RESUMO

Objetivo Es conocido el efecto de la hipoxia sobre el funcionamiento de las células ciliadas externas de la cóclea, que son las responsables de la respuesta a las otoemisiones utilizadas en el cribado auditivo neonatal. El objetivo de este estudio es conocer la influencia de variaciones leves o moderadas del pH de cordón umbilical al nacer en el resultado del cribado auditivo con otoemisiones en recién nacidos sanos sin factores de riesgo auditivo. Resultados La muestra está compuesta de 4.536 niños sanos. Los resultados no muestran diferencias significativas en el resultado del cribado auditivo entre el grupo de pH asfíctico (<7,20) y normal. Tampoco se detecta una cifra de pH inferior a 7,20 en la muestra que se relacione con alteración en el cribado. Desglosando en subgrupos con factores conocidos de variación en el resultado del cribado, como es el género o la lactancia, tampoco se detectan diferencias significativas de respuesta. El Apgar ≤ 7 sí se relaciona significativamente con un pH<7,20. Conclusiones En conclusión, las situaciones de asfixia leve-moderada asociadas al parto de recién nacidos sanos sin factores de riesgo auditivo no alteran el resultado del cribado con otoemisiones. (AU)


Objective The effect of hypoxia on the functioning of the outer hair cells of the cochlea, which are responsible for the response to otoemissions used in neonatal hearing screening, is well known. The aim of this study is to determine the influence of mild to moderate variations in umbilical cord pH at birth on the outcome of hearing screening with otoemissions in healthy newborns without hearing risk factors. Results The sample is composed of 4536 healthy infants. The results show no significant differences in the hearing screening outcome between the asphyctic (<7.20) and normal pH group. Nor is a figure below 7.20 detected in the sample that is related to an alteration in the screening. When broken down into subgroups with known factors of variation in the screening result, such as gender or lactation, no significant differences in response were detected. Apgar ≤ 7 is significantly related to pH<7.20. Conclusions In conclusion, mild-moderate asphyxia associated with delivery of healthy newborns, without auditory risk factors, does not alter the outcome of otoemission screening. (AU)


Assuntos
Humanos , Recém-Nascido , Sangue Fetal/química , Emissões Otoacústicas Espontâneas , Triagem Neonatal , Cordão Umbilical/química , Cóclea , Células Ciliadas Auditivas Externas , Hipóxia , Estudos Retrospectivos
8.
Artigo em Chinês | MEDLINE | ID: mdl-38297849

RESUMO

Objective:This study aims to analyze the threshold changes in distortion product otoacoustic emissions(DPOAE) and auditory brainstem response(ABR) in adult Otof-/- mice before and after gene therapy, evaluating its effectiveness and exploring methods for assessing hearing recovery post-treatment. Methods:At the age of 4 weeks, adult Otof-/- mice received an inner ear injection of a therapeutic agent containing intein-mediated recombination of the OTOF gene, delivered via dual AAV vectors through the round window membrane(RWM). Immunofluorescence staining assessed the proportion of inner ear hair cells with restored otoferlin expression and the number of synapses.Statistical analysis was performed to compare the DPOAE and ABR thresholds before and after the treatment. Results:AAV-PHP. eB demonstrates high transduction efficiency in inner ear hair cells. The therapeutic regimen corrected hearing loss in adult Otof-/- mice without impacting auditory function in wild-type mice. The changes in DPOAE and ABR thresholds after gene therapy are significantly correlated at 16 kHz. Post-treatment,a slight increase in DPOAE was observeds,followed by a recovery trend at 2 months post-treatment. Conclusion:Gene therapy significantly restored hearing in adult Otof-/- mice, though the surgical delivery may cause transient hearing damage. Precise and gentle surgical techniques are essential to maximize gene therapy's efficacy.


Assuntos
Orelha Interna , Perda Auditiva , Camundongos , Animais , Emissões Otoacústicas Espontâneas/fisiologia , Audição/fisiologia , Perda Auditiva/genética , Perda Auditiva/terapia , Terapia Genética , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Proteínas de Membrana
9.
J Acoust Soc Am ; 155(1): 358-379, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38236807

RESUMO

The Wentzel-Kramers-Brillouin (WKB) approximation is frequently used to explore the mechanics of the cochlea. As opposed to numerical strategies, the WKB approximation facilitates analysis of model results through interpretable closed-form equations and can be implemented with relative ease. As a result, it has maintained relevance in the study of cochlear mechanics for half of a century. Over this time, it has been employed to study a variety of phenomena, including the limits of frequency tuning, active displacement amplification within the organ of Corti, feedforward mechanisms in the cochlea, and otoacoustic emissions. Despite this ubiquity, it is challenging to find rigorous exposition of the WKB approximation's formulation, derivation, and implementation in cochlear mechanics literature. In this tutorial, the foundations of the WKB approximation are discussed in application to models of one- and two-dimensional cochlear macromechanics. This includes mathematical background, rigorous derivation and details of its implementation in software.


Assuntos
Cóclea , Modelos Biológicos , Emissões Otoacústicas Espontâneas
10.
J Speech Lang Hear Res ; 67(2): 668-679, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38295290

RESUMO

PURPOSE: The purpose of this study was to develop a time-efficient music exposure and testing paradigm that safely creates temporary cochlear dysfunction that could be used in future temporary threshold shift (TTS) studies. METHOD: A 30-min audio compilation of pop rock music tracks was created. Adult volunteers with normal hearing were then exposed to this music material monaurally through headphones for 30 min at 97 dBA or 15 min at 100 dBA. Levels were measured from the ear of a manikin and are considered to provide an equivalent daily noise dose based on a 3-dB exchange. We assessed the changes in their hearing, by means of distortion product otoacoustic emission (DPOAE) testing, and standard and extended high-frequency pure-tone audiometry before and after exposure. There were 17 volunteers in total. In the first trial, eight volunteers (four females; Mdnage = 31 years [interquartile range, IQR = 4.25]) were included. Although TTS was observed in all eight participants for at least one frequency, a large variation in affected frequencies was observed. To address this issue, the audio material was further remastered to adjust levels across the different frequency bands. Fourteen adults (nine newly recruited and five from the first trial; seven females; Mdnage = 31 years [IQR = 5]) were exposed to the new material. RESULTS: All but two of 17 participants presented clinically significant TTS or decrease in DPOAE amplitude in at least one frequency. Statistically significant average TTS of 7.43 dB was observed at 6 kHz. There were statistically significant average DPOAE amplitude shifts of -2.55 dB at 4 kHz, -4.97 dB at 6 kHz, and -3.14 dB at 8 kHz. No participant presented permanent threshold shift. CONCLUSIONS: A monaural music paradigm was developed and shown to induce statistically significant TTS and DPOAE amplitude shifts, without evidence of permanent loss. This realistic and time-efficient paradigm may be considered a viable option for experimental studies of temporary music-induced hearing loss. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.25016471.


Assuntos
Perda Auditiva Provocada por Ruído , Música , Adulto , Feminino , Humanos , Ruído , Emissões Otoacústicas Espontâneas , Audiometria de Tons Puros , Limiar Auditivo
11.
Int J Pediatr Otorhinolaryngol ; 177: 111862, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38295684

RESUMO

OBJECTIVE: Increasing options are becoming available for clinicians and healthcare professionals who use smartphone-based applications (apps) to identify hearing loss. The use of smartphone-based apps for newborn hearing screening (NHS) has been proposed as an alternative screening method in NHS programs. This study aims to compare the screening outcomes of a smartphone-based otoacoustic emission (OAE) screening device to a commercially available OAE screening device. METHODS: NHS was conducted in the post-natal maternity ward and neonatal intensive care unit (NICU) of two tertiary public healthcare hospitals over a period of 8 months. Within participant DPOAE and TEOAE screening outcomes of a smartphone-based OAE device (hearOAE) were compared to that of the Otodynamics ILO V6. RESULTS: A total of 176 infants (n = 352 ears; 48.9 % female) underwent NHS (DPOAE n = 176; TEOAE n = 176). The mean age at was 4.5 days (SD 11.3). Signal-to-noise ratio (SNR) were higher with the hearOAE with TEOAE NHS, and equivalent or higher SNR at four out of six frequencies with DPOAEs. Mean and total noise levels were significantly lower for the hearOAE compared to the Otodynamics with DPOAEs noise levels of five out of six frequencies being equivalent to, or lower than the Otodynamics (p < 0.001). Lower noise levels are likely to be advantageous in less-than-ideal test conditions. Inter-device DPOAE comparison indicated no statistically significant difference in the refer rate between the devices (p = 0.238). DPOAE pass rates between devices differed in 6 ears (p > 0.05), and in 20 ears for TEOAEs, with the hearOAE demonstrating a higher TEOAE pass rate (p = 0.009). The hearOAE did, however, demonstrate lower noise levels at three out five frequencies, which may have impacted the pass rate. No statistically significant correlation was found between the independent variables and the screening outcome (pass/refer) for TEOAEs using either device (p = 0.105 to 0.810). A high concordance of NHS outcomes within-participants of 89.7 % and 85.0 % for DPOAE and TEOAE respectively, was measured. CONCLUSIONS: The mHealth based OAE device demonstrated good agreement in NHS outcomes compared to a commercially available device. This verifies the performance of the novel smartphone based OAE device, and may facilitate increased accessibility of decentralised NHS service in resource constrained populations.


Assuntos
Emissões Otoacústicas Espontâneas , Smartphone , Gravidez , Recém-Nascido , Lactente , Humanos , Feminino , Masculino , Testes Auditivos/métodos , Triagem Neonatal/métodos , Centros de Atenção Terciária
12.
Artigo em Inglês | MEDLINE | ID: mdl-37391167

RESUMO

The effect of hypoxia on the functioning of the outer hair cells of the cochlea, which are responsible for the response to otoemissions used in neonatal hearing screening, is well known. The aim of this study is to determine the influence of mild to moderate variations in umbilical cord pH at birth on the outcome of hearing screening with otoemissions in healthy newborns without hearing risk factors. The sample is composed of 4536 healthy infants. The results show no significant differences in the hearing screening outcome between the asphyctic (<7.20) and normal pH group. Nor is a figure below 7.20 detected in the sample that is related to an alteration in the screening. When broken down into subgroups with known factors of variation in the screening result, such as gender or lactation, no significant differences in response were detected. Apgar ≤7 is significantly related to pH<7.20. In conclusion, mild-moderate asphyxia associated with delivery of healthy newborns, without auditory risk factors, does not alter the outcome of otoemission screening.


Assuntos
Cóclea , Emissões Otoacústicas Espontâneas , Lactente , Feminino , Humanos , Recém-Nascido , Cóclea/fisiologia , Testes Auditivos/métodos , Fatores de Risco , Concentração de Íons de Hidrogênio
13.
Ear Hear ; 45(2): 505-510, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37759362

RESUMO

OBJECTIVES: Clinical practice guidelines predicate the need for evaluation of hearing in children with otitis media with effusion (OME). The objective of this work was to characterize the completeness of hearing assessment results in children with OME. DESIGN: Forty participants with OME completed two full audiological assessments, one in a clinical setting and a second in a research setting. An additional 14 participants without OME completed a single audiological assessment in the research setting as a control group. The success of various behavioral and objective audiometric tests in each setting was quantified and evaluated. RESULTS: Findings indicate that ear-specific behavioral audiometric information is substantially limited in children with OME, particularly in clinical settings. In contrast, objective testing including tympanometry and otoacoustic emission testing was largely successful. CONCLUSIONS: Ear-specific behavioral audiometric information is limited in children with OME and, consequently, consideration of these data for use as part of clinical decision making is also limited. Objective tests were more successful but are not direct measures of hearing.


Assuntos
Otite Média com Derrame , Otite Média , Criança , Humanos , Otite Média com Derrame/diagnóstico , Audiometria , Testes de Impedância Acústica , Emissões Otoacústicas Espontâneas
14.
Ear Hear ; 45(2): 329-336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37700446

RESUMO

OBJECTIVES: To evaluate the extent of hearing loss among pottery workers in Mexico exposed to lead. DESIGN: The authors conducted a cross-sectional study including 315 adult pottery workers. Auditory function was evaluated by air conduction pure-tone audiometry (pure-tone average) and distortion-product otoacoustic emission (DPOAE) levels (amplitude and signal-to-noise ratio). Lead exposure was assessed with a single blood sample test and classified as low, medium, and high according to blood lead tertiles. Logistic regression models were calculated for the association between blood lead levels, pure-tone average, and DPOAE records. RESULTS: Median (25th-75th) blood lead levels were 14 µg/dL (7.5-22.6 µg/dL). The audiometric pattern and DPOAE records were similar across blood lead levels groups in all frequencies, and no statistically significant differences were found. Adjusted logistic regression models showed no increase in the odds for hearing thresholds >25 dB (HL) and DPOAE absence associated with blood lead levels, and no dose-response pattern was observed ( p > 0.05). CONCLUSIONS: Given the results from this cross-sectional study, no association was found between blood lead levels and hearing loss assessed with DPOAE. Future longitudinal work should consider chronic lead exposure estimates among underrepresented populations, which can potentially inform safer work practices to minimize the risk of ototoxicity.


Assuntos
Surdez , Perda Auditiva , Ototoxicidade , Adulto , Humanos , Chumbo , Ototoxicidade/etiologia , Estudos Transversais , Limiar Auditivo/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Perda Auditiva/induzido quimicamente , Audiometria de Tons Puros/métodos
15.
Ear Hear ; 45(2): 465-475, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37990395

RESUMO

OBJECTIVES: This study aims to develop deep learning (DL) models for the quantitative prediction of hearing thresholds based on stimulus-frequency otoacoustic emissions (SFOAEs) evoked by swept tones. DESIGN: A total of 174 ears with normal hearing and 388 ears with sensorineural hearing loss were studied. SFOAEs in the 0.3 to 4.3 kHz frequency range were recorded using linearly swept tones at a rate of 2 Hz/msec, with stimulus level changing from 40 to 60 dB SPL in 10 dB steps. Four DL models were used to predict hearing thresholds at octave frequencies from 0.5 to 4 kHz. The models-a conventional convolutional neural network (CNN), a hybrid CNN-k-nearest neighbor (KNN), a hybrid CNN-support vector machine (SVM), and a hybrid CNN-random forest (RF)-were individually built for each frequency. The input to the DL models was the measured raw SFOAE amplitude spectra and their corresponding signal to noise ratio spectra. All DL models shared a CNN-based feature self-extractor. They differed in that the conventional CNN utilized a fully connected layer to make the final regression decision, whereas the hybrid CNN-KNN, CNN-SVM, and CNN-RF models were designed by replacing the last fully connected layer of CNN model with a traditional machine learning (ML) regressor, that is, KNN, SVM, and RF, respectively. The model performance was evaluated using mean absolute error and SE averaged over 20 repetitions of 5 × 5 fold nested cross-validation. The performance of the proposed DL models was compared with two types of traditional ML models. RESULTS: The proposed SFOAE-based DL models resulted in an optimal mean absolute error of 5.98, 5.22, 5.51, and 6.06 dB at 0.5, 1, 2, and 4 kHz, respectively, superior to that obtained by the traditional ML models. The produced SEs were 8.55, 7.27, 7.58, and 7.95 dB at 0.5, 1, 2, and 4 kHz, respectively. All the DL models outperformed any of the traditional ML models. CONCLUSIONS: The proposed swept-tone SFOAE-based DL models were capable of quantitatively predicting hearing thresholds with satisfactory performance. With DL techniques, the underlying relationship between SFOAEs and hearing thresholds at disparate frequencies was explored and captured, potentially improving the diagnostic value of SFOAEs.


Assuntos
Aprendizado Profundo , Perda Auditiva Neurossensorial , Humanos , Audição , Emissões Otoacústicas Espontâneas/fisiologia , Perda Auditiva Neurossensorial/diagnóstico , Testes Auditivos/métodos , Limiar Auditivo/fisiologia , Estimulação Acústica/métodos , Cóclea/fisiologia
16.
Ear Hear ; 45(1): 250-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37677959

RESUMO

OBJECTIVES: Attenuation of otoacoustic emissions over time has been reported for many patients with hearing impairment harboring mutations in the OTOF gene. In this study, the time course of changes of distortion product otoacoustic emissions (DPOAEs) has been analyzed in a cohort of patients in the light of tympanometry results. DESIGN: The changes of DPOAEs in 16 patients with OTOF -related hearing impairment were retrospectively analyzed. RESULTS: All but one subject showed DPOAEs bilaterally at the time of diagnosis. Three patients diagnosed as adults still had DPOAEs at ages of 27, 31, and 47 years, respectively. Follow-up was available for 7 children diagnosed at the age of 1 to 3 years, who still showed preservation of DPOAEs at ages of 5 to 16 years. The responses were absent or attenuated in amplitude at some follow-up appointments in association with type B or C tympanograms. CONCLUSIONS: DPOAEs are preserved much longer than expected in a cohort of patients with OTOF -related hearing impairment. The previously reported loss of DPOAEs may have been caused in some children by increased middle ear impedance due to otitis media.


Assuntos
Perda Auditiva , Adulto , Criança , Humanos , Lactente , Pré-Escolar , Estudos Retrospectivos , Perda Auditiva/diagnóstico , Emissões Otoacústicas Espontâneas/fisiologia , Testes de Impedância Acústica , Orelha Média , Audiometria de Tons Puros , Limiar Auditivo/fisiologia , Proteínas de Membrana
17.
Laryngoscope ; 134(1): 433-438, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37421238

RESUMO

OBJECTIVE: Compare hearing outcomes utilizing standard, prolonged and delayed ganciclovir (GCV) therapy in a murine model of cytomegalovirus (CMV). METHODS: BALB/c mice were inoculated with mouse cytomegalovirus (mCMV) or saline via intracerebral injection on postnatal day 3 (p3). Intraperitoneal GCV or saline was administered at 12 h intervals for the duration of the standard (p3-p17), delayed (p30-p44), or prolonged treatment windows (p3-p31). Auditory thresholds were assessed using distortion product otoacoustic emission (DPOAE) and auditory brainstem response (ABR) testing at 4, 6, and 8 weeks of age. Blood and tissue samples were harvested from mice on p17 and p37 one hour after GCV administration, and their concentrations were assessed via liquid chromatography-mass spectrometry. RESULTS: A delayed course of GCV improved ABR but not DPOAE thresholds in mCMV-infected mice. A prolonged course of GCV did not provide better hearing thresholds than those administered standard treatment. The average GCV concentration in all 17-day-old mice tissue was significantly higher than those in older 37-day-old mice. CONCLUSION: Delayed GCV treatment provided a hearing benefit on ABR over untreated mCMV infected mice. Prolonged CGV administration showed no benefit compared to a shorter duration GCV treatment. GCV drug concentrations both systemically and in the cochlea are much lower in older mice. These results have potential implications for the clinical management of cCMV infected children. LEVEL OF EVIDENCE: NA Laryngoscope, 134:433-438, 2024.


Assuntos
Infecções por Citomegalovirus , Muromegalovirus , Humanos , Criança , Animais , Camundongos , Idoso , Ganciclovir/uso terapêutico , Infecções por Citomegalovirus/tratamento farmacológico , Citomegalovirus , Emissões Otoacústicas Espontâneas , Camundongos Endogâmicos BALB C , Antivirais/uso terapêutico
18.
Ear Hear ; 45(1): 115-129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37475147

RESUMO

OBJECTIVES: The contralateral medial olivocochlear reflex (MOCR) strength may indicate various auditory conditions in humans, but a clinically viable assay and equipment are needed for quick, accurate, and reliable measurements. The first experiment compared an earlier version of the assay, which used a nonlinear-mode chirp stimulus, with a new assay using a linear-mode click stimulus, designed to give reliable MOCR measurements in most normal-hearing ears. The second experiment extended the improved assay on a purpose-built binaural hardware platform that used forward-pressure level (FPL) calibration for both the stimulus and the contralateral MOCR elicitor. DESIGN: Transient-evoked otoacoustic emission (TEOAE) tests were measured with and without a 60-dB SPL MOCR-evoking contralateral broadband noise. The normalized MOCR strength (MOCR%) was derived from the TEOAE responses for each trial pair using the complex pressure difference weighted by the TEOAE magnitude. Experiment 1 compared MOCR% within-subject and across-day using two TEOAE stimuli: nonlinear-mode chirps (50 dB SPL, bandpass 1-5 kHz, 14 ms window delayed by 2 ms) and linear-mode clicks (50 dB SPL, bandpass 0.5-2.5 kHz, 13 ms window delayed by 5 ms). TEOAE responses were analyzed in the 0.5 to 2.5 kHz band. Thirty adult participants with normal hearing (30 ears) completed the study. The TEOAE stimulus was calibrated in situ using spectral flattening, and the contralateral noise was calibrated in a coupler. Twelve TEOAE trial pairs were collected for each participant and condition. Experiment 2 used a purpose-built binaural system. The TEOAE stimuli were linear-mode clicks (50 dB SPL, bandpass 1-3 kHz, 13 ms window delayed by 5 ms), analyzed in the 1 to 3 kHz band over ~12 trial pairs. After a probe refit, an additional trial pair was collected for the two early-stopping signal-to-noise ratio criteria (15 and 20 dB). They were evaluated for single-trial reliability and test time. Nineteen adult participants with normal hearing (38 ears) completed the study. The TEOAE clicks and contralateral elicitor noise were calibrated in situ using FPL and delivered with automated timing. RESULTS: MOCR% for linear-mode clicks was distinguishable from measurement variability in 98% to 100% of participants' ears (both experiments), compared with only 73% for the nonlinear-mode chirp (experiment 1). MOCR detectability was assessed using the MOCR% across-subject/within-subject variance ratio. The ratio in experiment 1 for linear-mode clicks was higher (8.0) than for nonlinear-mode chirps (6.4). The ratio for linear-mode clicks (8.9) in experiment 2 was slightly higher than for the comparable linear-mode stimulus (8.0) in experiment 1. TEOAEs showed excellent reliability with high signal-to-noise ratios in both experiments, but reliability was higher for linear-mode clicks than nonlinear-mode chirps. MOCR reliability for the two stimuli was comparable. The FPL pressure response retest reliability derived from the SPL at the microphone was higher than the SPL retest reliability across 0.4 to 8 kHz. Stable results required 2 to 3 trial pairs for the linear-mode click (experiments 1 and 2) and three for the nonlinear-mode chirp (experiment 1), taking around 2 min on average. CONCLUSIONS: The linear-mode click assay produced measurable, reliable, and stable TEOAE and MOCR results on both hardware platforms in around 2 min per ear. The stimulus design and response window ensured that any stimulus artifact in linear mode was unlikely to confound the results. The refined assay is ready to produce high-quality data quickly for clinical and field studies to develop population norms, recognize diagnostic patterns, and determine risk profiles.


Assuntos
Audição , Emissões Otoacústicas Espontâneas , Adulto , Humanos , Reprodutibilidade dos Testes , Emissões Otoacústicas Espontâneas/fisiologia , Cóclea/fisiologia , Reflexo , Estimulação Acústica/métodos
19.
Eur Arch Otorhinolaryngol ; 281(3): 1273-1283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37831131

RESUMO

PURPOSE: Newborns who fail the transient evoked otoacoustic emissions (TEOAE) but pass the automatic auditory brainstem response (AABR) in universal newborn hearing screening (UNHS), frequently have no further diagnostic test or follow-up. The present study aimed to investigate whether hearing loss might be missed by ignoring neonatal TEOAE failure in the presence of normal AABR. METHODS: A retrospective analysis was conducted in newborns presenting between 2017 and 2021 to a tertiary referral centre due to failure in the initial UNHS. The main focus was on infants who failed TEOAE tests, but passed AABR screening. The clinical characteristics and audiometric outcomes were analysed and compared with those of other neonates. RESULTS: Among 1,095 referred newborns, 253 (23%) failed TEOAE despite passing AABR screening. Of the 253 affected infants, 154 returned for follow-up. At 1-year follow-up, 46 (28%) achieved normal audiometric results. 32 (21%) infants had permanent hearing loss (HL) confirmed by diagnostic ABR, 58 (38%) infants had HL solely due to middle ear effusion (MEE), and for 18 (12%) infants HL was suspected without further differentiation. The majority of permanent HL was mild (78% mild vs. 13% moderate vs. 9% profound). The rate of spontaneous MEE clearance was rather low (29%) leading to early surgical intervention in 36 children. The profile of the risk factors for hearing impairment was similar to that of newborns with failure in both, TEOAE and AABR; however, there was a stronger association between the presence of risk factors and the incidence of HL (relative risk 1.55 vs. 1.06; odds ratio 3.61 vs. 1.80). CONCLUSION: In newborns, the discordance between a "refer" in TEOAE and a "pass" in AABR screening is associated with a substantial prevalence of hearing impairment at follow-up, especially in the presence of risk factors.


Assuntos
Surdez , Perda Auditiva , Lactente , Criança , Humanos , Recém-Nascido , Estudos Retrospectivos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Emissões Otoacústicas Espontâneas , Testes Auditivos/métodos , Triagem Neonatal/métodos , Perda Auditiva/diagnóstico , Perda Auditiva/epidemiologia
20.
Hear Res ; 441: 108928, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38086151

RESUMO

Auditory complaints are frequently reported by individuals with mild traumatic brain injury (mTBI) yet remain difficult to detect in the absence of clinically significant hearing loss. This highlights a growing need to identify sensitive indices of auditory-related mTBI pathophysiology beyond pure-tone thresholds for improved hearing healthcare diagnosis and treatment. Given the heterogeneity of mTBI etiology and the diverse peripheral and central processes required for normal auditory function, the present study sought to determine the audiologic assessments sensitive to mTBI pathophysiology at the group level using a well-rounded test battery of both peripheral and central auditory system function. This test battery included pure-tone detection thresholds, word understanding in quiet, sentence understanding in noise, distortion product otoacoustic emissions (DPOAEs), middle-ear muscle reflexes (MEMRs), and auditory evoked potentials (AEPs), including auditory brainstem responses (ABRs), middle latency responses (MLRs), and late latency responses (LLRs). Each participant also received magnetic resonance imaging (MRI). Compared to the control group, we found that individuals with mTBI had reduced DPOAE amplitudes that revealed a compound effect of age, elevated MEMR thresholds for an ipsilateral broadband noise elicitor, longer ABR Wave I latencies for click and 4 kHz tone burst elicitors, longer ABR Wave III latencies for 4 kHz tone bursts, larger MLR Na and Nb amplitudes, smaller MLR Pb amplitudes, longer MLR Pa latencies, and smaller LLR N1 amplitudes for older individuals with mTBI. Further, mTBI individuals with combined hearing difficulty and noise sensitivity had a greater number of deficits on thalamic and cortical AEP measures compared to those with only one/no self-reported auditory symptoms. This finding was corroborated with MRI, which revealed significant structural differences in the auditory cortical areas of mTBI participants who reported combined hearing difficulty and noise sensitivity, including an enlargement of left transverse temporal gyrus (TTG) and bilateral planum polare (PP). These findings highlight the need for continued investigations toward identifying individualized audiologic assessments and treatments that are sensitive to mTBI pathophysiology.


Assuntos
Concussão Encefálica , Perda Auditiva , Humanos , Concussão Encefálica/diagnóstico , Limiar Auditivo/fisiologia , Audição/fisiologia , Ruído , Potenciais Evocados Auditivos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Emissões Otoacústicas Espontâneas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...